儀器名稱: N5222A PNA Microwave Network Analyzer 26.5GHZ---徐經(jīng)理 18912657535 儀器型號: N5222A -2port 儀器品牌: Agilent 儀器指標(biāo): 10 MHz to 26.5 GHz

  Key Features & Specifications

  • 10 MHz to 26.5 GHz
  • 2-ports with single source or 4-ports with two built-in sources
  • 127 dB system and 132 dB receiver dynamic range, 32,001 points, 200 channels, 15 MHz IF bandwidth
  • High output power (+13 dBm) and a wide power sweep range (38 dB)
  • Best dynamic accuracy: 0.1 dB compression with +12 dBm input power at the test port
  • Low noise floor of -114 dBm at 10 Hz IF bandwidth

 Description

Highest performance network analyzer that meets your budget

The PNA Series is the highest-performing microwave network analyzer in the industry for passive and active device test. You can choose from five frequency models, 13.5, 26.5, 43.5, 50, or 67 GHz, and customize your PNA with the just the right level of performance to meet your specific budget and measurement needs.

The Agilent PNA is used to test a wide variety of passive and active devices such as filters, duplexers, amplifiers and frequency converters. The high-performance characteristics of the PNA make it an ideal solution for these types of component characterizations as well as millimeter-wave, signal integrity and materials measurements.

Most accurate S-parameter measurements

The PNA Series provides high-power sources and the best linear receivers, giving it the most accurate S-parameter measurements with the widest power range in the market.

Applications

  • S-parameters (CW and pulsed)
  • Noise figure
  • Gain compression
  • Intermodulation and harmonic distortion
  • Conversion gain/loss
  • True-differential stimulus
  • Millimeter-wave
  • Material measurements
  • Signal integrity
  • Antenna test

PNA Firmware, Upgrade and Support

 
N5222A-008Pulsed RF Measurements
N5222A-010Time Domain
N5222A-020Add IF inputs
N5222A-021Add pulse modulator to internal first source
N5222A-022Add pulse modulator to internal second source
N5222A-025Add four internal pulse generators
N5222A-028Noise figure measurements using standard receivers
N5222A-080Frequency offset measurements
N5222A-082Scalar calibrated converter measurements
N5222A-083Vector and scalar calibrated converter measurements
N5222A-084Embedded LO measurements
N5222A-086Gain compression application
N5222A-087Intermodulation distortion measurements
N5222A-088Source phase control
N5222A-118Fast CW Mode
N5222A-1A7Calibration + Uncertainties + Guardbanding
N5222A-1CMRack mount kit for installation without handles
N5222A-1CPRack mount kit for installation with handles
N5222A-200

2 ports, single source, base hardware configuration 

2 ports, single source, base hardware configuration

N5222A-200

View Details

N5222A-201

2 ports, single source, with configurable test set 

2 ports, single source, with configurable test set

N5222A-201

View Details

N5222A-2102 ports, single source, with metrology configuration
N5222A-217

2 ports, single source, configurable test set, extended power range 

2 ports, single source, configurable test set, extended power range

N5222A-217

View Details

N5222A-219

2 ports, single source, configurable test set, extended power range, bias-tees 

2 ports, single source, configurable test set, extended power range, bias-tees

N5222A-219

View Details

N5222A-301Application for use with standard CalPods
N5222A-302Application for use with temperature-characterized CalPods
N5222A-400

4 ports, dual source, base hardware configuration 

4 ports, dual source, base hardware configuration

N5222A-400

View Details

N5222A-401

4 ports, dual source, with configurable test set 

4 ports, dual source, with configurable test set

N5222A-401

View Details

N5222A-4104 ports, dual source, with metrology configuration
N5222A-417

4 ports, dual source, configurable test set, extended power range 

4 ports, dual source, configurable test set, extended power range

N5222A-417

View Details

N5222A-419

4 ports, dual source, configurable test set, extended power range, bias-tees 

4 ports, dual source, configurable test set, extended power range, bias-tees

N5222A-419

View Details

N5222A-460Integrated true-mode stimulus application
N5222A-551N-port calibrated measurements
N5222A-897Built-in performance test software for inclusive calibration, perpetual license
N5222A-898Built-in performance test software for standards compliant calibration, perpetual license
N5222A-A6JANSI Z540-1-1994 Calibration
N5222A-UK6Commercial calibration certificate with test data
N1966A

Pulse/IO Adapter 

Pulse/IO Adapter

N1966A

  • Adapter for connecting between Pulse I/O connector and coaxial inputs and outputs of external pulse generators and external pulse modulators

View Details

N6171A

MATLAB Software 

MATLAB Software

N6171A

  • Create arbitrary waveforms
  • Customize measurement/data analysis routines, instrument applications/test systems
  • Automate measurements, signal generation, report generation
  • Available directly from Agilent with purchase of compatible instrument

View Details

N6171A-M01

MATLAB-Basic Package, individual license - node-locked 

MATLAB-Basic Package, individual license - node-locked

N6171A-M01

  • Basic configuration includes:
  • MATLAB software environment
  • Instrument Control Toolbox

View Details

N6171A-M02

MATLAB-Standard Package, individual license - node-locked 

MATLAB-Standard Package, individual license - node-locked

N6171A-M02

  • Standard MATLAB configuration includes:
  • MATLAB software environment
  • Instrument Control Toolbox
  • Communications Toolbox
  • DSP System Toolbox
  • Signal Processing Toolbox

View Details

N6171A-M03

MATLAB-Advanced Package, individual license - node-locked 

MATLAB-Advanced Package, individual license - node-locked

N6171A-M03

  • Advanced MATLAB configuration includes:
  • MATLAB software environment
  • Instrument Control Toolbox
  • Communications Toolbox
  • Signal Processing Toolbox
  • DSP System Toolbox
  • RF Toolbox

View Details